Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/99770436-sdzw2000t-sl/bg6e.png)
102
Parameter
Function
Anti-dither
System only memorizes one event during the anti-dither period. The
unit is second, the value ranges from 0s to 100s.
Manual Control
Excluded
Click it and it will generate motion detection event when excluding
manual control, which can reduce the false alarm rate of motion
detection event.
Record
Check it and so when alarm occurs, system will auto record. You
shall set record period in Storage>Schedule and select auto record
in record control interface.
Record Delay
System can delay the record for specified time after alarm ended.
The value ranges from 10s to 300s.
Relay out
Check it to enable alarm activation output port, it can activate
corresponding alarm output device when alarm occurs.
Alarm delay
It means alarm delays a period of time to stop after alarm ends, the
unit is second, and the value ranges from 10s to 300s.
Send Email
If you enabled this function, System can send out email to alert you
when alarm occurs. User can set email address in Network>SMTP.
PTZ
Here you can set PTZ movement when alarm occurs. Such as
go to preset x when there is an alarm.
The event type includes: preset, tour and pattern.
Snapshot
You need to check the box here so that system can backup motion
detection snapshot file. You shall set snapshot period in
Storage>Schedule.
Table 4-24
Step 3
Click “Save” to complete config.
4.4.1.2 Video Tamper
Step 1
Select “Setup > Event > Video Detect > Video Tamper”.
The system will display the interface of “Video Tamper”, which is shown in Figure 4-80.
Loading ...
Loading ...
Loading ...