f. If the adjustment will not align the display
readout to the bevel index positions, refer to
the trouble shooting guide in this manual
g. When the encoder alignment has been com-
pleted, the electronic indicator system should
be ready for use.
Using the Electronic Indicator System
1. Setting the indicator reference points.
In order to establish the starting location point of
the blade, it is necessary to set the indicator
references at zero. Normally, these zero refer-
ences are the front of the fence, the top of the
table, and with the face of the blade square to
both of these surfaces. However, many instances
will require selection of the reference points to fit
the woodworking operations to be performed.
Place the blade or cutting tool in the exact
position and angle that you have selected as the
zero reference position.
Turn the display "On" by pressing _ key.
tho a, ,efooo,,ooke . ress
to set the zero reference angle for the
bevel readout. 1
This displav should read: BEy .0
Press the [_'TER]I key. Press _ to set the
zero reference angle for the miter readout.
This display should read: _,T .0]
Pressthe key.Press tose, thezero
reference location for the blade elevation
readout.
This display should read: [EL_ .00 !
Press _ key. Press [_ to set the
zero reference location for in-riD. The indicator
display should read: [,,, .00!
If "O-Rip" is displayed, press _] again.
Before pressing _ key to set the zero
reference location for the blade in-rip location
readout.
The display should now read: I",_ .00]
Press the _ key again. The "O-Rip"
indicator display should now appear. Press
[_,sET! , the display should read: [o-,,, .00
To set out-rip reference point, swivel theyoketo
the out-rip position. Move rip fence to rear
position and measure 10 inches from rip fence's
front side.
NOTE: The saw will be very close to this point. The
radial arm rear travel stop will not allow the blade
any closer to fence than approximately 10 inches. To --_
accurately set the reference, measure with tape
measure or ruler to determine exactly !0 inches from
fence to the blade.
When blade is 10 inches from fence, push _
key once to zero and then a second time to set
reference point. The display should read [o-,,p I0.00]
.03
.06
.09
.12
_ .16
.19
.22
.25
FENCE
DECIMAL EQUIVALENTS
NOTE: All decimals are rounded
to the nearest .01 inch.