Loading ...
Loading ...
Loading ...
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii__ ili!_ii_!_i_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_ii_i,lililililiiililiiililililiiililiiililililiiililiiililililiiililiiililililiiililiiililililiiililiiililililiiililiiililililiiililiiililililiiililiiililililiiililiiililililiiililiiililililiiililiiililililiiililiiiiiii_;_!i_i!_i!!_!ii!_i!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!if!ii!il!il!ii!ii!ii!ii!i_ili!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!i!i!i!i_!i_ii_i!i_iii10!_i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_'i_!i
Intermittent sparking Ceramic igniter is wet or dirty.
Burner ports are clogged.
More than four clicks of Improper fit of burner cap onto
igniter before lighting burner base.
Constant Sparking Range is not properly grounded.
Electrical power supply is incorrectly
polarized.
Carefully dry or clean igniter.
Clean ports on burner cap with a wire, a
needle or straightened paper clip.
Align burner cap properly on burner base.
Refer to Installation Instructions. Have a
qualified electrician ground the range
properly.
Refer to Installation Instructions.
Have a qualified electrician ground the
range properly.
Before Calling For Service
Before calling for service, check the following to avoid
unnecessary service charges.
Be sure to check these items first:
Is there a power outage in the area?
Is the household fuse blown or the circuit breaker
tripped?
Is the range disconnected from the electrical supply?
If the Burners do not Ignite
Are the burner caps properly aligned and seated in the
burner bases?
Are the burner ports clogged?
Is a fuse blown or is the circuit breaker tripped?
Is the manual shut-off valve closed, preventing the flow
of gas?
Data Rating Plate
The data rating plate shows the model and serial number of
your range. It is located on the frame, behind the oven door
(See illustration).
Figure 25: Rating Plate and Wiring Diagram Locations
(oven door not shown)
The electric wiring diagrams and schematics in the toe kick
area should not be removed except by a service technician.
Replace after service.
CAUTION:
Before removing the toe kick panel, disconnect
the range from the electrical power supply.
Reinstall the toe kick panel before reconnecting
the range to the power supply and operating the
range.
English 33
Loading ...
Loading ...
Loading ...