Hikvision DS-TMC407-EHCURVED BOOM POLE All-in-one E&E machine with capture unit, curved boom pole and LCD

User Manual - Page 17

For DS-TMC407-EHCURVED BOOM POLE.

PDF File Manual, 70 pages, Read Online | Download pdf file

DS-TMC407-EHCURVED BOOM POLE photo
Loading ...
Loading ...
Loading ...
Figure 2-1 Acvate via SADP
Status of the device becomes Acve aer successful acvaon.
5.
Modify IP address of the device.
1) Select the device.
2) Change the device IP address to the same network segment as your computer by either
modifying the IP address manually or checking Enable DHCP.
3) Enter the admin password and click Modify to acvate your IP address modicaon.
2.1.3 Acvate via Web Browser
Use web browser to acvate the device. For the device with the DHCP enabled by default, use
SADP soware or client soware to acvate the device.
Before You Start
Ensure the device and the computer connect to the same LAN.
Steps
1.
Change the IP address of your computer to the same network segment as the device.
2.
Open the web browser, and enter the default IP address of the device to enter the acvaon
interface.
3.
Create and conrm the admin password.