Troubleshooting
arp -s <IP address> <serial number> temp
ping -s 408 <IP address>
In Windows, type the following from a command/DOS prompt (this may require that you run the command pro mpt as
an admin istra tor):
arp -s <IP address> <serial number>
ping -l 408 -t <IP address>
2. If the product d o es not reply in 30 seconds, restart it and wait for a reply. Press CTRL+C to stop Ping.
3. Open a browser and type in the product’s IP address. In the page that ap pears, use the Browse button to select the upgrade
le to use . Then click Load to restart the upgrade process.
4. After the upgrade is complete (1–10 minutes), the product automatically restarts and shows a steady green on the Status
indicator.
5. Reinstall the product, refe rring to the Installation Guide.
If the emergency recovery procedure does not get the product up and running again, contact Axis support at www.axis.com/techsup/
Symptoms, Possible Causes and Remedial Actions
Problems setting the IP address
When using ARP/Ping
Try the ins talla tion again. The IP address m ust b e set within two minutes after power has been
applied to the product. Ensure the Ping length is set to 408. See the Installation Guide for
detailed instructions.
The product is locate d on a
different subnet
If the IP address intended for the product and the IP address of the computer used to access the
product are located on different subnets, you w ill not be able to set the IP address. Contact your
network administrator to obtain an IP address.
The IP address is being u sed
by another device
Disconnect the Axis product from the network. Run the Ping command (in a Command/DOS
window, type ping and the IP address of the product:
•Ifyoureceive:Reply from <IP address>: bytes=32; time=10...
this means that the IP address may already be in use by another device on the netwo rk.
Obtain a new IP address from the network administrator and reinstall the product.
•Ifyoureceive:Request timed out, this means that the IP address is available for
use with the Axis product. C heck all cabling and reinstall the product.
Possible IP address conict
with another device on the
same subnet.
The static IP address in the Axis product is used before the DHCP server sets a dynamic address.
This means that if the same default static IP addressisalsousedbyanotherdevice,theremay
be problems accessing the product.
The product cannot be accessed from a browser
Cannot log in
When HTTPS is enabled, ensure that the correct protocol (HTTP or HTTPS) is used when attem pting
to log in. You m
ay need to manually type http or https in the browser’s address eld.
If the pas
sword for root is lost, the product must be reset to the factory default settings. See
Reset to Factory Default Settings, on page 44
.