LIGHTS EXPLANATION OF LIGHTS OPERATION
blinking
The setting of the grinding level adjust-
ment selector is incorrect, or beyond
the maximum adjustment possible
Return the selector to one of the regular set-
tings (between 1 and 8), remembering that:
• The grinding adjustment must be made
with the mill in operation
• The mill should be adjusted one level
at a time, and used at least 5 times be-
tween one adjustment and the next
OUT of correct
range
Correct
range
permanently on
The machine calls for tamping The coee has just been ground and the lter
holder is attached to the coee mill
The lter holder has been detached
from the coee mill without tamping
Release the lter holder and proceed, tamp-
ing the coee as described in section “The
“perfect dose”” “When using pre-ground
coee:”
The lter holder has been released with
grinding incomplete, or the tamping
step has occurred too quickly
Repeat the grinding step
The coee mill funnel is clogged
Clean as described in section “8.5 Cleaning the
“Smart tamping station””. If the problem per-
sists, access the funnel by opening the relative
cover and clear the blockage using the tube
brush
The burrs are jammed by foreign matter Remove the foreign matter and clean the
burrs as indicated in section “8.3 Cleaning
the burrs”.
permanently on
(red)
Descaling is required Carry out descaling as described in section
“11. Descaling”
blinks
(red)
+
blinks
(orange)
Descaling is in progress Complete the operation as described in sec-
tion “11. Descaling”
blinks
(red)
+
permanently on (white)
Rinsing is required
→
Correct range OUT OF
correct range