TROUBLE SHOOTING m ELECTRONICS
TROUBLE REMEDY
Flashing "C" in 1. See "Calibrating The Saw For Electronic Operations"
display when Master p. 29.
Switch is turned "ON".
No display or failure
of electronic function
Steady "C" in display.
Flashing display.
Elevation or bevel motor
tries to run but stops.
_-_ key does not
function.
Elevation motor runs
slow or noisily
Bevel motor runs slow
or is noisy,
Elevation or bevel motor
stops before reaching
target number or will not
run. Saw is not jammed.
Depth of cut or blade
angle incorrect.
Display does not
respond correctly
to keys.
CAUSE
1. Power Interruption
2. Saw just plugged in and
not calibrated
1. No power to unit.
2. Master Switch "OFF".
3. Electronics failure
1.A function key has been
pressed but saw has not
been calibrated.
1. Elevation or bevel
positioning motor jammed
against stop.
1. No elevation or bevel keyed
in or saw is already at
desired elevation or bevel
2. Elevation greater than
plus or minus 4.095
inches.
1. Elevation screw threads
filled with pitch & sawdust.
1. Tilt Screw threads filled .with
pitch & sawdust.
1. Positioning motor overheated
1. Saw not properly calibrated.
1. Static Electricity
1. Check plug, fuse, or circuit breakers. Inspect line,
cord and plug for damaged insulation and shorted wires.
2. Turn Master Switch "ON".
3. Have electronics checked by qualified service
technician, repair service is available at your
nearest Sears store.
1. See "Calibrating The Saw For Electronic Operations"
p. 29.
1. Press Jog keys to pull away from stop.
1. Key in correct elevation or bevel.
2. Press _ key and key in correct elevation.
1. Clean threads & lubricate
1. Clean threads & lubricate
1. Allow to cool for at least 10 minutes.
1. See "Calibrating The Saw For Electronic Operations"
p. 29
1. Turn master switch "OFF" then "ON". If
still not right unplug saw from power supply
momentarily. Recalibrate saw p 29.
If you require further help on operating your new
Craftsman Electronic Table Saw call 800-325-1184.
In Missouri call 314-595-2500.