52 | City Series CC40E-11
installation
Vent Guard - if required*
(Part #946-506/P)
Notes:
1. Liner sections should be continuous without any joints
or seams.
2. Only Flex pipe purchased from Regency
®
may be used
for Flex installations
3. Horizontal vent must be supported every 3 feet.
4. Flex system can only be used up to a maximum
continuous vent length of up to 10 feet. If longer runs
are required, rigid pipe must be used.
Horizontal Terminations - Flex Vent 4" x 6-7/8"
These venting systems, in combination with the CC40LE/CC40RE Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by
Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations"
section.
Regency
®
Direct Vent (Flex) System Termination Kits includes all the parts needed to install the CC40LE/CC40RE using a flexible vent.
FPI Kit # Length Contains:
#946-513 2 Feet 1. 6-7/8” flexible outer liner (Kit length)
2. 4” flexible inner liner (Kit length)
3. spring spacers
4. thimble
5. AstroCap termination cap
6. screws
7. tube of Mill Pac
8. plated screws
9. S.S. screws #8 x 1-1/2” drill point
#946-515 4 Feet
#946-516 10 Feet