20 | City Series CC40E-11
owner's information
Outer Safety Glass Panel (Barrier Glass) Installation / Removal
Note: safety glass panels must be installed to operate fireplace.
Note: If the outer safety glass side panels angle too far inward or outward,
remove the side glass panel and adjust on the panel angle bracket,
see details on previous page.
5. Lift up the side panel with the supplied glass clamps (see procedure on
previous page). Tilt the side of the glass panel inward and lift up and under-
neath the upper side panel and hook the 2 outer hooks on to the pins, there
is also a panel angle adjustment bracket for the third hook.
Note: The side frame upper panel is shown as transparent to better
illustrate the install (this area is not visible when installing glass).
4. For 3 sided and corner units only:
With front panel installed, proceed to install the side panel(s).
Identify the left and right side panels before installing. Facing the front of
the unit, the right panel will show an arrow pointing to the front of the unit
as shown in the diagram below.
Note: After the side panel has been adjusted so it is installed at 90º to the
unit and not flaring in or out, check to ensure there is no gap between
the front and side panel. If there is a gap as shown below, slide the side
panel to adjust the position and close the gap.
Direction arrow on side
panel bracket, should
point toward front of
unit
6. Repeat Steps 4 and 5 to install the opposite side panel.
7. Reverse Steps to remove all panels.
Note: When removing panels, we recommend using the supplied glass clamps.