City Series CC40E-11 | 51
installation
Vent restriction is required for certain venting installations, see the diagrams in the "Venting
Arrangements" section to determine if they are required for your installation.
The Vent Restrictor plate is packed in the instruction manual package.
To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;
1. Remove the safety glass and firebox glass - see instructions in this manual.
2. Remove the screws that hold the vent restrictor plate in place (see Diagram 1)
3. Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown.
4. Once the vent restrictor plate is in the required position, secure with screws.
Vent Restrictor Position (Part # 656-017F)
Vent restrictor positions:
Set 0 (Full open) Factory set
Set 1 (Vent restrictor at 2”)
Set 2 (Vent restrictor at 1.75”)
Set 3 (Vent restrictor at 1.5”)
Vent restrictor location - inside top of firebox
Diagram 1
Screw
locations