Virtual PTZ and Full Image Recording
3.4.3 SpecialM16CongurationintheBrowser
M16andDierentSensorModules
A range of combination options are provided that change
the available display modes and conguration possibilities
by using the MOBOTIX M16 with dierent sensor modules.
Because of this, a M16 automatically detects which sensor
modules are installed and proceeds as follows:
•
When the camera is started for the rst time, it detects
the connected sensor modules and captures their
data (focal length, day or night version).
• If only one sensor module is connected, the camera
acts as a mono camera (meaning that there is no
automatic day/night switching, etc.).
• If there is no change within the rst 12 hours of ope
-
ration, the camera writes the details of these sensor
modules to the camera conguration.
•
With every restart, the camera checks if the stored sen-
sor modules are present. If the sensor conguration
has changed in the meantime (e.g., because a sensor module has been exchanged),
the camera shows a corresponding message in the live image
. To store the changed
sensor conguration in the camera, proceed as described at the end of Section 3.4.3,
«Special M16 Conguration in the Browser».
CongurationoftheM16BasicParametersforHemisphericSensorModules
Thanks to its hemispherical lens, the MOBOTIX M16 provides certain
special conguration options for the image settings. Depending on
where the camera is installed (ceiling, wall or
oor) and on the live image display preferred
by the user, certain important basic settings and,
if necessary, their adjustment must be congured
when a M16 is rst installed.
Sensor module B016* Sensor modules B036*, B041*,
B061*, B079*, B119*, B237*
Sensor module B500*
*For an explanation of
the sensor module des-
ignations (e.g., B016),
please read Section 1.2.1,
«M16 Lens Options»