42 UTD1000L User Manual
To measure AC Current within 1mA-40mA, do the following:
1. Press I button to set measurement type to AC Current,
2. Press F3 to select mA range, the measurement unit will change into mA accordingly.
2. Plug mA current module (UT-M10) properly into input terminals COM andV/Ω, then turn the
switch on the module to 40mA range.Insert Black and Red test leads correspondingly into
Black and Red terminals on the module.
4. Connect test leads to tested points, then take the AC current reading.
Figure 5-18 Measuring AC Current Lower than 40mA
To measure AC Current within40mA-400mA, do the following:
1. Press I button to set measurement type to AC Current,
2. Press F3 to select mA range, the measurement unit will change into mA accordingly.
3. Plug mA current module (UT-M10) properly into input terminals COM andV/Ω, then turn the
switch on the module to 400mA range.
4. Insert Black and Red test leads correspondingly into Black and Red terminals on the module.
5. Connect test leads to tested points, then take the AC current reading.