Remote Operation
Remote Command Summary16
16-27
SYNCOUT <cpd> Set the sync output <ON>, <OFF>,
<AUTO>, <WFMSYNC>, <POSNMKR>,
<BSTDONE>, <SEQSYNC>,
<TRIGGER>, <SWPTRG> or
<PHASLOC>.
TONEEND <nrf> Delete tone frequency number <nrf>
thus defining the end of the list.
TONEFREQ <nrf1>,<nrf2>,
<nrf3>
Set tone frequency number <nrf1> to
<nrf2> Hz. The third parameter sets the
tone type; 1 will give trig, 2 will give FSK,
any other value gives gate.
TRIGIN <cpd> Set the trig input to <INT>, <EXT>,
<MAN>, <PREV>, <NEXT>, <POS> or
<NEG>.
TRIGOUT <cpd> Set the trig output to <AUTO>,
<WFMEND>, <POSNMKR>, <SEQSYNC>
or <BSTDONE>.
TRIGPER <nrf> Set the internal trigger generator period to
<nrf> sec.
VAIN <cpd> Set the MODULATION or SUM input to
<VCA>, <SUM> or <OFF>.
WAVE <cpd> Select the output waveform as <SINE>,
<SQUARE>, <TRIANG>, <DC>,
<POSRMP>, <NEGRMP>, <COSINE>,
<HAVSIN>, <HAVCOS>, <SINC>,
<PULSE>, <PULSTRN>, <ARB> or
<SEQ>.
WAVFREQ <nrf> Set the waveform frequency to <nrf>
Hz.
WAVPER <nrf> Set the waveform period to <nrf> sec.
ZLOAD <cpd> Set the output load, which the generator is
to assume for amplitude and dc offset
entries, to <50> (50 ), <600>
(600 ) or <OPEN>.