Introduction to the VENUE | S6L System 11
Operational Requirements
Temperature and Ventilation
S6L system devices should be operated away from heat sources and with adequate ventilation.
Storage
S6L system devices should be stored and transported at temperatures not lower than 0 degrees F (–18 degrees C) and not exceeding
140 degrees F (60 degrees C).
Operation
S6L system devices should be operated at temperatures not lower than 40 degrees F (4 degrees C) and not exceeding 104 degrees F
(40 degrees C).
During operation, the left and right end caps on the back of the S6L control surface, the front and back of the E6L engine, and the
fans on the back of the Stage 64 should be exposed to ambient air. Do not block the ventilation holes on any S6L system component.
Do not operate in direct sunlight or at extreme ambient temperatures.
Water and Moisture
S6L system devices should be operated away from sources of direct moisture and should be kept clear of liquids that might spill
into the units. If condensation is present on the unit, leave the unit to dry in ambient air for at least one hour before powering the
unit on.
Cleaning and Maintenance
Use a dry cloth to clean the surfaces of the S6L components. Do not apply any cleaning solutions, spray cleaners, or abrasives
to the surfaces of the components.
Use a microfiber cloth (included with the S6L control surface) to clean the touch screens. Do not apply any cleaning solutions,
spray cleaners, or abrasives.
Hardware monitoring and automatic warnings are provided for temperature, power and other factors. For more information,
see
Hardware Monitoring Window.
Storage humidity range 5% to 95%, non-condensing
Operating humidity range 20% to 80%, non-condensing