DXS-3400 Series Lite Layer 3 Stackable 10GbE Managed Switch Web UI Reference Guide
388
Parameter Description
• Error Frame Seconds - This feature is used to enable notifying the Ethernet
OAM error frame second event and configure the monitor threshold and
window on the specified port.
• Error Frame Period - This feature is used to enable notifying the Ethernet
OAM error frame period event and configure the monitor threshold and
window on the specified port.
Notify State
Select to enable or disable the notify state here.
Threshold
Enter the threshold value here.
• When Error Symbol is selected as the link monitor, enter the number of
symbol errors here. If symbol errors occur in the specified window and it
exceeds the threshold value, then the event is generated. The range is from
0 to 4294967295.
• When Error Frame is selected as the link monitor, enter the number of frame
errors here. If the error frames occur in the specified window and exceeds
the threshold value, then an error frame event is triggered. The range is from
0 to 4294967295.
• When Error Frame Seconds is selected as the link monitor, enter the
number of error frames in seconds here. If the number of the error frames
occurred in the specified window and exceeds the threshold value, then the
frame event is triggered. The range is from 1 to 900 seconds.
• When Error Frame Period is selected as the link monitor, enter the number
of frame errors that must occur for this event to be triggered here. The range
is from 0 to 4294967295.
Window
Enter the window value here.
• When Error Symbol is selected as the link monitor, enter the amount of time
over which the threshold is defined here. If threshold symbol errors occur
within the period, an event notification OAM PDU should be generated with
an error symbol period event TLV, indicating that the threshold has been
crossed in this window. The range is from 10 to 600 deciseconds.
• When Error Frame is selected as the link monitor, enter the amount of time
over which the threshold is defined here. If the threshold frame errors occur
within the period, an event notification OAM PDU will be generated with an
error frame event TLV, indicating that the threshold has been crossed in this
window. The range is from 10 to 600 deciseconds.
• When Error Frame Seconds is selected as the link monitor, enter the
amount of time over which the threshold is defined here. If threshold frame
errors occur within the period, an event notification OAM PDU will be
generated with an error frame seconds summary event TLV indicating that
the threshold has been crossed in this window. The range is from 100 to
9000 deciseconds.
• When Error Frame Period is selected as the link monitor, enter the number
of frames over which the threshold is defined here. If threshold frame errors
occur within the period, an event notification OAM PDU should be generated
with an error frame period event TLV indicating that the threshold has been
crossed in this window. The lower bound is the number of minimum frame-
size frames that can be received in 100ms on the underlying physical layer.
The upper bound is the number of minimum frame-size frames that can be
received in one minute on the underlying physical layer. The range is from
148810 to 89286000.
Click the Apply button to accept the changes made.