Program data
Operating data module -
Programme data
Delete data e
\ A
After selecting program data the following (example)
will appear in the display:
Operating data module~ Programme data
1 Cottons 90 °C
2 Cottons universal 60 °C e
\ A
Select the program you want from the list and press
the rotary dial to call up a list of all program starts
including date and start time for that program.
Programme data ~ 1 Cottons
Date: 21.05.2010 Start time: 11:30
Date: 21.05.2010 Start time: 12:30 e
\ A
Select the required program start from the list for
program 1 Cottons and confirm your choice by
pressing the rotary dial.
Programme data ~ 1 Cottons
Date: 21.05.2010
Name: Smith e
\ A
Other options:
Town: Abingdon
Serial number: 12345678
Machine type: PW 6107
Amount of laundry: 13 kg
+ Button: Activated
Starch stop button: Activated
Without spin button: Not activated
Programme start: 11:30
Programme finished: 12:05
Total operating time:0h35min
Electrical energy: 12.5 kWh
Gas energy: 0 kWh
Steam energy: 0 kWh
Total volume of water: 140 l
Max. water temperature: 95 °C
Max. drain temperature: 45 °C
Programme change: 2
(after making your selection and
pressing the rotary dial only the last 3 stops and starts will
be displayed.)
Programme fault: None (only the last 3 faults are saved.)
Area 1: Pre-wash (after making your selection and
pressing the rotary dial you can display the area or the
block.)
Operating time: 6 min
Water volume: 20 l
Dispensing phase 1: Amount ml
(after making your
selection and pressing the rotary dial 6 dispensings are
displayed.)
Max. temperature: 12 °C
Holding time: 6 min
Dispensing phase 2: No
Delete data
Operating data module
Programme data
Delete data e
\ A
After selecting Delete data the following message will
appear in the display:
Operating data module~ Delete data
Module: 21.02.2010
Total data: 12.07.2010 e
\ A
The module menu option can be used to delete the
total data and program data from the operating data
memory.
The total data option can only be used to delete the
total data from the operating data.
The program data option can only be used to delete
program data from the operating data.
After making your selection and pressing the rotary
dial you will be prompted to enter your password.
Password:____
ABCDEFGHIJKLMNOPQRSTUVWXYZ
0123456789
KSA
After keying in your password or inserting your
supervisor level key card in the reader the following
security prompt will appear in the display:
Delete operating data?
S A
After pressing the S button the data will be deleted!
Optional modules