![](https://files.manualsfile.com/Nilfisk-SC800-manual/bg28.png)
Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 40
9. Remove 4 screws securing the Main Machine Controller and remove it from the cover.
10. Reassemble in reverse order, taking care not to damage the printed circuit ribbons used to connect the circuit
board to the control switch interface panel.
11. Set Mandatory Program Opons - IMPORTANT! When a new controller is installed, it must rst be told how the
machine is equipped before it will work. The rst me the key is turned on, the controller wakes up in the pro-
gramming opon mode to “force” you to complete the sengs. In this special case, you will be walked through
seng the Scrub Deck Type and Baery Charger Selecon before the machine will operate. See Programming
Opons – SC750 ST and SC800 ST Models (Control Panel with rocker switches) - Mandatory Program Opons.
Main Machine Controller SC750 ST and SC800 ST Models (Later Build)
Minor changes were made to the electrical panel cover and circuit breaker panel to make the machine easier to
service. Follow the instructions for “Main Machine Controller SC750 and SC800 Models (control Panel with
membrane switches) Later build “ with the realization that some of the photos will not exactly match the ma-
chine you are working on.
Main Machine Controller SC750 and SC800 Models (Early Build)
Note: Electronic devices like the Main Machine Controller are sensive to Electrostac Discharge (ESD). Before handling
the controller, touch a metal bench or shelf to discharge any electrical charge that may have built up in your body. Do not
walk around with a controller in your hands.
1. Completely drain soluon tank. This is important for the soluon level sensor to work properly upon reassembly.
2. Turn o and remove key.
3. Disconnect Handle electrical connector. Remove top two handle bolts and loosen the lower two. Rotate Handle
Assembly down.
Loading ...
Loading ...
Loading ...