Restore Factory Defaults – This funcon is used to reset all sengs to factory default values. If this is done, the next
me the key is turned on, it will act as though a new controller has been installed and “force” you to set the mandatory
program opons before the machine will operate normally.
To check or change the seng:
1. While pressing and holding the vacuum switch forward and scrub and soluon switches
backward, turn the key switch on.
2. Wait about 3 seconds unl all of the LEDs light up and then go o. Release the switches.
The Regular Scrub Pressure Indicator will remain on and the Fault Indicator will be ashing a numeric value that repre-
sents the current seng. To change the seng, press the soluon switch forward to increase the value or backwards to
decrease the value. To save the seng, press the scrub forward (All LEDs will turn on) then turn o the key switch.
• 1 blink = No
• 2 blinks = Yes
Fault Recall – The fault indicator normally ashes out “current” codes only. This funcon is used by a technician to check
for “historical codes” and clear them.
To check or clear historical codes:
1. While pressing and holding the vacuum and soluon switches backward and the scrub
switch forward, turn the key switch on.
2. Wait about 3 seconds unl all of the LEDs light up and then go o. Release the switches.
The High Soluon Flow Indicator will remain on and the Fault Indicator will be ashing out all historical codes set since
the last me they were cleared. To exit this funcon without clearing codes, press the scrub switch forward. To clear
historical codes press the soluon switch forward.
Fault Detecon - Normally, the Main Machine Controller will perform checks of the electrical system during operaon. If
a fault occurs in a parcular system, that system (and possibly others) will be shut down. This can make troubleshoong
the system dicult. This opon will allow service personnel to disable some of the fault detecon checks to facilitate
troubleshoong. This will not disable the over-current protecon on any of the systems.
To check or change the seng:
1. While pressing and holding the vacuum and soluon switches forward, turn the key
switch on.
2. Wait about 3 seconds unl all of the LEDs light up and then go o. Release the switches.
The Medium Soluon Flow Indicator will remain on and the Fault Indicator will be ashing a numeric value that repre-
sents the current seng. To change the seng, press the soluon switch forward to increase the value or backwards to
decrease the value. To save the seng, press the scrub switch forward (All LEDs will turn on) then turn o the key switch.
• 1 blink = Fault Detecon Enabled
• 2 blinks = Fault Detecon Disabled