Form Number 56043150 Page 154
Trip Type Type Description Trip Code Code Description and Possible Causes
Undened 300 Parallel Speed Pot. Wiper Error
This occurs when the controller detects that the Parallel
Speed Limit Potentiometer Wiper is open circuit or has been
shorted to one of the throttle references. The Parallel Speed
Limit Potentiometer Wiper input is located on pin 9 of the
14-way Tiller Connector. If this error occurs, the controller
will allow drive to continue but at the minimum programmed
speed. Check the parallel speed potentiometer, connections
and relevant wiring to the i-Drive.
If the trip is still present after the potentiometer, connectors
and wiring have been checked, the controller may be defec-
tive. Refer to Section 3.
Undened 4401 Record Of Possible Control Fault.
‘4401’ is not actually a trip code but rather a historical record
of the number of times the i-Drive has tripped with a suspect-
ed controller fault. Each time the i-Drive trips with an error
not shown in the table above, it records one instance of the
code ‘4401’ in the controllers System Log. The actual con-
troller trip code is also recorded in the i-Drive’s Control Log.
The number of ‘4401’ trips shown in the System Log should
therefore equal the cumulative number of trip occurrences
shown in the Control Log. More information on the i-Drive’s
diagnostic logs can be found in Chapter 3, Section 12. Check
the batteries, motor, connectors and wiring to the i-Drive.
Please contact PGDT for further advice before returning a
controller based solely on the presence of historical ‘4401’
trips in the System Log.
* Dependant on programming
Trip Types 4 and 5 not used for i-Drive
Section 3 Servicing Of Defective Units
There are no serviceable parts within the controller. Opening or making any unauthorized adjustments or modi-
caons to the controller or its components will invalidate any warranty and may result in hazards to the operator
and is strictly forbidden.