![](https://files.manualsfile.com/Nilfisk-SC800-manual/bg88.png)
Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 136
8. Remove control panel cover.
9. Disconnect wiring from electrical components on electrical panel.
10. Disconnect the pressure sensor hose at the soluon tank end.
11. Thread wiring out of soluon tank.
12. Remove squeegee li cable.
13. Remove soluon tank shut o valve elbow from tank.
14. Remove 4 soluon tank mounng bolts.
15. Separate tank from frame.
• Soluon valve winding resistance – 54 ohms
• Soluon ow – Maximum = 0.75 gallons/minute
• Detergent pump winding resistance –37 ohms