Binder FP 240 Drying and heating ovens

User Manual - Page 74

For FP 240.

PDF File Manual, 91 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
FP (E1.1) 03/2019 page 74/90
Chamber size
53
115
240
400
720
Ventilation data
Air change
at 70 °C
x/h
59
29
19
17
11
at 150 °C
x/h
64
32
20
18
12
at 300 °C
x/h
53
26
18
16
10
Electrical data
(model versions FP053-230V, FP115-230V, FP240-230V, FP400-230V, FP720-230V
IP system of protection acc. to EN 60529
20
20
20
20
20
Nominal
voltage
(+/-10%)
at 50 Hz power frequency
V
230
230
230
400
400
at 60 Hz power frequency V 230 230 230 400 400
Current type
1N~
1N~
1N~
3N~
3N~
Nominal power
kW
1,20
1,60
2,70
3,40
5,00
Chamber fuse 5 x 20 mm 230V / time-lag (T)
10 A
external
10 A
external
-- -- --
Chamber fuse 5 x 20 mm 230V / middle-time-
lag
(M)
-- --
16 A
external
-- --
Over-current release category B -- -- --
3 x 16A
internal
3 x 16A
internal
Power plug
shock proof plug
CEE plug 5 poles
Installation category acc. to IEC 1010-1
II
II
II
II
II
Pollution degree acc. to IEC 1010-1
2
2
2
2
2
Different electrical data for FP-UL constructed for the USA and Canada
(model versions FP053UL-120V, FP115UL-120V, FP240UL-120V, FP400UL-120V, FP720UL-120V)
Nominal voltage (+/-10%)
at 60 Hz power frequency
V 115 115 208 208 208
Current type
1N~
1N~
3N~
3N~
3N~
Power plug
NEMA
5-20P
5-20P
L21-20P
L21-20P
L21-20P
Chamber fuse 6,3 x 32 mm / 250V /
super-time-lag TT
A
16
16
16
16
20
external external
3 x
internal
3 x
internal
3 x
internal
Installation category acc. to IEC 1010-1
II
II
II
II
II
Pollution degree acc. to IEC 1010-1
2
2
2
2
2
Environment-specific data
Energy consumption
at 70 °C
Wh/h
145
230
370
520
570
at 150 °C
Wh/h
300
544
850
1200
1320
at 300 °C
Wh/h
720
1100
1400
2340
2600
All technical data is specified for unloaded chambers with standard equipment at an ambient temperature
of +22 °C +/- 3°C / 71.6 °F ± 5.4 °F and a power supply voltage fluctuation of ±10. Technical data is
determined in accordance to BINDER Factory Standard Part 1:2015 following DIN 12880:2007.
All indications are average values, typical for chambers produced in series. We reserve the right
to alter technical specifications at all times.
If the chamber is fully loaded, the specified heating up times may vary according to the load.
Loading ...
Loading ...
Loading ...