3. Set the number of cycles to infinite in the program start level and start the program
The described example program must be started once at the precise moment of temperature
change (on Monday e.g., at 0.01 or at 7.00). If the program cannot be manually started at the
desired moment, a suitable program delay-time of 99 hs. 59 min. max. can be programmed.
After rundown of this delay time the program starts automatically (see chap. 9).
Normal Display
Hit program key
Display 1 shows
1
actually selected program
Display 2 shows
SEL.PRG.
select program 1 or 2
Enter program number 1 with arrow keys
Value is displayed in display 1.
Hit program key
Display 1 shows
e.g. 00.00
(entered delay time hh.mm)
Display 2 shows
RUN TIME
(enter delay time of program start)
Set delay time, if desired, in hh.mm with
arrow keys
Setting 00.00 means no delay time (immediate
program start)
Value is displayed in display 1.
Hit program key
Display 1 shows
-1
actually selected number of program cycles: infinite
Display 2 shows
REPEAT
(enter number of program cycles)
Select number of cycles –1, i.e. infinite
repeats, with arrow keys
Value is displayed in display 1.
Hit program key
Display 1 shows
1
selected program
Display 2 shows
RUN PRG.
Question: start selected program?
Hit program key
Display 1 shows
20.0
C
actual temperature value
Display 2 shows
P01:S01 119:49
(time running
backwards)
actual program P01, actual section S01, and remaining time
of program section S01
Program is running. The green LED (3d) lights up.
Additionally to the green LED (3d) indicating a running program LED (3a) is lit if the heating is active, or
no LED if the actual temperature equals the set-point.
During program course the arrow keys and the EXIT button are not functional.
By hitting the program key the program course can be terminated.
If during program course button is hit, the entered set-points of the actually running program section
are shown one after the other for 5 sec. each.