Binder FP 240 Drying and heating ovens

User Manual - Page 34

For FP 240.

PDF File Manual, 91 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
FP (E1.1) 03/2019 page 34/90
The following section (in our example now S03) is displayed:
Display 1 shows
e.g. 03
(actually selected section: S03)
Display 2 shows
alternating
P01:S03
(program section can be selected)
CONTINUE X/W
(information: set-point entry with X/W)
Hit key
EXIT
or wait 120 sec
Controller returns to Normal Display
If you delete a program section which is followed by further sections, those following move up
to the place of the deleted section.
In our example section S03 has been deleted. Sections S04, S05, etc., in case they have been
programmed earlier, will now receive the preceding sections numbers, i.e., S04 is now called S03 etc.
It is thus not possible to temporarily inactivate a program section, but deletion leads to overwriting the
section by the following one. To enter a section later to a program also the sections following the new one
must be entered again.
9. Program start level
Before starting the program, check the set-point entered in Fixed value operation mode. After end of the
program, the temperature will equilibrate to this value. This value must not exceed the permitted drying
temperature for the used solvent quantity.
CAUTION
Too high or too low temperature after end of program.
Damage to the charging material.
Check the set-point of Fixed value operation and if necessary adapt it.
After end of the program, the temperature will equilibrate to the set-point entered in Fixed value operation
mode. If the week program timer is active, another set-point (SP2) might be targeted according to
programming. Inactivate the week program timer before starting the program (default setting, setting in
the User level, chap. 10).
CAUTION
Too high or too low temperature after end of program.
Damage to the charging material.
Inactivate the week program timer before starting the program.
In a first step a program is selected. This on condition that a program has been entered previously (chap.
8.2) and that program type “2 programs with 10 sections each” has been selected in the user level (chap.
10).
Then the settings for the program course are defined. Two parameters can be set:
Program delay time, i.e. a defined time before program start. It can be entered with precision of 1 min
and is max. 99.59 (99 hs 59 min). If the value is 00.00 the program is started without any delay.
Number of program cycles, i.e. the desired number of program repeats. Values from 1 to 99 can be
entered. If the program is not to be repeated, enter value 0. For infinite repeats enter value 1. The
program is repeated as a whole, it is not possible to repeat individual sections.
In a last step the selected program is started. These steps must be carried out subsequently.