Differential Temp
You can set the value of the minimum difference between the current
temperature and set temperature before the system calls to heat or
cool. A smaller difference means shorter cycle times, whereas a larger
difference results in longer cycle times. By default the differential temp
is 1°F which means if the heat is set to 65°F the thermostat will turn
the HVAC on when the temperature falls to 65°F. A higher differential
temp will help prevent unnecessary short cycles from wearing out
your heating/cooling system and reduce starting cost. The
temperature range is adjustable from 0.5ºF to 3°F (0.5ºC to 2°C) by
going to Settings > System > Differential Temp.
Minimum Comfort Zone
Minimum Comfort Zone is the minimum difference between the heat
mode set temperature and the cool mode set temperature when the
system mode is in Auto Mode. The delta is adjustable from 3ºF to
10°F (1.7ºC to 5.5°C). The default value is 5°F (2.8°C).
Temperature & Humidity Correction
Wyze Thermostat has built-in temperature and humidity sensors that
are calibrated during production. If the sensors seem to be
consistently reading slightly above or below the actual temperature or
humidity, you can adjust it with a reference thermometer. For example,
if the thermostat reading is higher than your reference temperature,
apply "-1". or "-2" in this setting.
You can update these features in Settings > Advanced >
Temperature Correction or Settings > Advanced > Humidity
Correction.
Minimum Runtime (Short Cycling
Protection-alternative name) (N/A)
If the compressor is restarted too soon after a shutdown, system
damage can occur. This feature allows the compressor to wait a few
minutes before restarting, helping to prevent damage to the heating or
cooling system. During the brief wait period, the thermostat will show
Cool on (or Heat on if you have a heat pump) until the wait period is
over, at which point the compressor will turn back on. The time is 5
minutes by default, but you can adjust it from 2 to 8 minutes by going
to Settings > System > Minimum Runtime.
Changing Measurement Units
You can switch between using Celcius and Fahrenheit by going to
Settings > Advanced > Temperature Units.
Note: this setting will be applied on both Wyze Thermostat and the
Wyze app when adjusting and displaying the temperature. The unit for
system settings will always be in Fahrenheit.
HVAC Accessories (* Terminal)
Wyze Thermostat offers an accessory terminal that is capable of
connecting to 1 of the following 4 devices:
1. Dehumidifier. To configure the dehumidifier, select:
1. Cooling: Dehumidifier will only run when cooling stage
is active and the humidity is outside the desired range.
2. Fan: Run the fan when the dehumidifier is active.
3. Energize: Active on or Active off.