RIGOL Chapter 2 Command System
2-152 DSA800 Programming Guide
[:SENSe]:TOI:FREQuency:SPAN
Syntax
[:SENSe]:TOI:FREQuency:SPAN <freq>
[:SENSe]:TOI:FREQuency:SPAN?
Description
Set the span of the TOI measurement.
Query the span of the TOI measurement.
Parameter
Name
Type
Range
Default
<freq>
Consecutive Real Number 100 Hz to 7.5 GHz 2 MHz
Explanation
This command is only available when the TOI measurement is enabled.
This setting changes the span of the spectrum analyzer.
Return Format
The query returns the span in integer and the unit is Hz.
Example
The command below sets the span to 1 MHz.
:SENSe:TOI:FREQuency:SPAN 1000000
The query below returns 1000000.
:SENSe:TOI:FREQuency:SPAN?
[:SENSe]:TPOWer:AVERage:COUNt
Syntax
[:SENSe]:TPOWer:AVERage:COUNt <integer>
[:SENSe]:TPOWer:AVERage:COUNt?
Description
Set the number of averages of the T-power measurement.
Query the number of averages of the T-power measurement.
Parameter
Name
Type
Range
Default
<integer>
Integer 1 to 1000 10
Explanation
This command is only available when the T-power measurement is enabled.
Return Format
The query returns the number of averages in integer.
Example
The command below sets the number of averages to 100.
:SENSe:TPOWer:AVERage:COUNt 100
The query below returns 100.
:SENSe:TPOWer:AVERage:COUNt?