Note
This funcon is only available for certain device models under certain sengs. Please refer to
the actual seîž«ngs.
Sensivity
It stands for the percentage of the body part of an acceptable target that goes across the
predened region. Sensivity = 100 - S1/ST × 100. S1 stands for the target body part that goes
across the predened region. ST stands for the complete target body. The higher the value of
sensivity is, the more easily the alarm can be triggered.
Target Validity
If you set a higher validity, the required target features should be more obvious, and the
alarm accuracy would be higher. The target with less obvious features would be missing.
Figure 10-3 Set Rule
5.
Oponal: You can set the parameters of mulple areas by repeang the above steps.
6.
For the arming schedule seîž«ngs, refer to Set Arming Schedule . For the linkage method seîž«ngs,
refer to Linkage Method Seîž«ngs .
7.
Click Save.
10.3.4 Set Region Exing Detecon
It is used to detect objects exing from a predened virtual region. If it occurs, the device can take
linkage acons.