Loading ...
Loading ...
Loading ...
![](https://files.manualsfile.com/14280309-ids-2cd7a46g0-h-izhsy/bg76.png)
10.6.1 Set Heat Map
If you want to query stascal data of heat map, please congure the camera rst.
Before You Start
●
Go to VCA and select the applicaon. Select People Management and click Next to enable the
funcon.
●
For the device supporng HEOP, go to VCA to import and enable People Management.
●
Set the storage path rst before searching heat map data. For the storage sengs, refer to
Storage Sengs .
Steps
1.
Go to VCA → Set Applicaon → People Management → Heat Map Conguraon .
2.
Check Enable to enable the funcon.
3.
Draw a detecon area. Click , click on the live view to specify the vertexes and draw the
boundaries of the detecon area, and right click to complete drawing.
4.
Congure the parameters for the drawn area.
Expected Number of People
It refers to the max. number of people for heat map counng.
ON
It refers to that the camera will compare the max. number of the people in the actual
scene with the set expected number of people and take the larger one as the max.
number of people for heat map.
OFF
It refers to that the camera will take the actual number of people as the max. value of heat
map.
5.
Click Save.
6.
Set arming schedule. See Set Arming Schedule .
7.
Set linkage method. See Linkage Method Sengs .
8.
Oponal: Click Data Upload to set the data uploading informaon. Click Save to save the
sengs.
Uploading Data Type
Dwell Time
It refers to the target's dwelling me in the detecon area.
Dwell Time and Number of People
It refers to the target's dwelling me in the detecon area and the people number in the
detecon area.
What to do next
The heat map stascs will be calculated under Applicaon Display tab. Go to Applicaon Display
to check the heat map stascs.