Karcher 1.217-111.0 Water treatment unit WRH 1200 classic

User Manual - Page 16

For 1.217-111.0.

PDF File Manual, 200 pages, Read Online | Download pdf file

1.217-111.0 photo
Loading ...
Loading ...
Loading ...
- 7
Order No. 5.033-239.0
Order No. 4.414-014.0
Order No. 4.901-090.0
Special funnel to fill in the active carbon fil-
ter filling
Order No. 2.641-831.0
Additional active carbon filter
Order No. 2.641-521.0
Manual switching between processed/
fresh water for using fresh water in the
high-pressure cleaner (for e.g. for rinsing).
Order No. 4.640-230.0
To throttle a raw water pump that is running
too high.
Order No. 2.641-510.0
Usage water ventilation to avoid bother-
some odours
Order No. 2.641-868.0
Second floater switch in the pump basin,
emits signal to external alarm setup, if the
pump basin is too full
Order No. 2.641-849.0
Support legs for filter module, if a wall
mounting is not possible
Order No. 6.474-073.0
Immersion pump as raw water pump
We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.
The signatories act on behalf of and with
the authority of the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Straße 28-40
71364 Winnenden (Germany)
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2018/10/01
Notice
The equipment may only be installed by an
mechanic of Kärcher
or an from Kärcher authorized individu-
al
The following requirements are necessary
in order to install the equipment:
frost-free room with adequate ventila-
tion and exhausts
sufficient lighting at the installation site
Floor path for collecting sludge
Strong wall for fastening the system
The ground must be stabile and tight.
Unpack the equpiment and dispose of the
packing material properly.
The machine must have an FI fuse of type
B, 30 mA.
The electrical connection of the system
may only be performed by a qualified elec-
trician. Please follow the respective nation-
al regulations!
Electrical installation as per IEC 60364-1
The water installation depends on the spe-
cific conditions of the existing plant compo-
nents such as
Type and model of high pressure clean-
er
NOTICE
The processed water outlet of the system is
directly connected to the water inlet of the
high-pressure cleaner. This can lead to
foam formation in the swimmer tank in
high-pressure cleaners with a swimmer
tank. In such a case, the high-pressure
cleaner must be switched to suction opera-
tioins (see separate operating instructions
of the high-pressure cleaner).
Type and models of building-side com-
ponents (sludge collector, pump basin,
etc.)
Nominal widtht, lengths and type of
channels
Hence, the water installation must be done
according to the specific local conditions.
The immersion pump specifications in the
building must meet the requirements out-
line in the "Technical Data / Immersion
Pump Requirements" section.
DANGER
Risk of injury on account of tripping and fall-
ing.
Lay the hoses of the plant in such a way
that they do not pose a risk for tripping and
falling.
NOTICE
During startup, set the multi-channel valve
to the position "BACKWASH" and rinse the
system until all bubbles have escaped from
the filament filter. After that, set the multi-
channel valve to "FILTRATION".
Accessories
Filter inlay
Filter fill active carbon filter
Funnel
Attachment kit active carbon filter
Attachment set 'Fresh water switching'
Attachment set input valve
Attachment kit ventilation
Attachment kit overflow
Attachment kit support leg
Immersion pump
EU Declaration of Conformity
Product: Effluent treatment plant
Type: 1.217-xxx
Relevant EU Directives
2006/95/EEC
2014/30/EU
Applied harmonized standards
EN 60204–1
EN 55014–1: 2006+A1: 2009+A2: 2011
EN 55014–2: 2015
EN 61000–3–2: 2014
EN 61000–3–3: 2013
EN 62233: 2008
Chairman of the Board of Management
Director Regulatory Affairs & Certification
Installing the unit (only for ex-
perts)
Preparing the installation place
Unpack the equipment
Electrical installation
Water installation
16 EN