8
If the installation area is not level, find the high point of this perimeter line. The floor, floor screed and wall must be leveled
to this point.
Use a 4’ level to determine floor levelness. Be sure to check both directions for floor levelness.
Cam Action Panel Fasteners
Before starting to assemble the unit, be sure to familiarize yourself with the operation of the panel fasteners.
To operate the cam locks, insert a 5/16” hex wrench (packed in hardware box) through the access hole in the panel interior
skin, and into the hex opening in the fastener. Turn the wrench clockwise approximately 3/4 of a turn to put the cam hook
into the locked position.
If a problem should occur, such as having to unlock a panel that was not properly positioned, you must turn the handle
counterclockwise until it stops, in order to reset the cam position.