4.3.9 RS-232 Wiring
Note
There is 1 RS-232 interface on the extended interface of access control board, see Access Control
Board Terminal Descripon (Oponal) . The RS-232A corresponds to UART 1 on web.
There is 1 RS-232 interface on the sub extended interface board, see Sub Extended Interface
Board Terminal Descripon . The RS-232B corresponds to UART 2 on web.
The RS-232C interface is reserved.
Figure 4-11 RS-232 Wiring
4.3.10 Alarm Input Wiring
On the main lane control board, you can wire the re alarm input interface.
Figure 4-12 Remaining Open
4.3.11 Exit Buon Wiring
The main and sub lane control board each has 1 buon interface, which can be connected to exit
buon or face recognion device.