4. For Pelco Camera Link, Sensitivity = 6 and Consistency = 2 are the recommended settings to start
with, but may need to be adjusted depending on the scene.
5. Calibrate the scene. A Calibrate page appears.
6. On the Calibrate page, place the blue box at a distant point in the view and adjust the height of the
box to match the height of a typical object at that distance. If needed, enter the height in the entry
box.
7. Select Set Width and position and adjust the length of the yellow bars of a typical object at a close
distance, and at a far distance.
8. When complete, select Return to Main Menu. This returns to the Analytics Page.
9. Set Exclude Zone for the 2 Camera Tracking Analytic. The analytic detects motion over the entire
Optera scene. However, if desired, a portion of the scene can be excluded from the analytic. For
example, a portion of the scene below is viewing inside the building through the windows. If only the
motion over the patio is desired, excluding the building windows is possible using the Exclude zone
tools.
10. Activate the behavior.
11. Click Save. This saves the setup for analytics into the Optera camera memory. As with settings for
Pelco cameras, a backup copy of settings can be saved by selecting Backup from the system Tab.
12. Click Run.