Lines" is set to 800, the correct relationship between them is as follows:
Of Lines
Interlace
Of Fields
Trigger Line
Trigger Field
800
1:1
1
800
1
800
2:1
1/2/4/8
400
1/1~2/1~4/1~8
800
4:1
1/2/4/8
200
1/1~2/1~4/1~8
800
8:1
1/2/4/8
100
1/1~2/1~4/1~8
Set the video trigger for video signal
Touch Sync for trigger mode selection, video trigger mode has "Any" and
"Select" options. In "Any" mode, the video signal can be triggered on any line
that meets the conditions. In "Select" mode, the signal can be triggered by a
specified field and a specified line.
For progressive scanning signals (e.g. 720p/50, 720p/60, 1080p/50, 1080p/60),
only the specified line can be selected to trigger when the synchronization mode
is Select.
For interlaced scanning signals (such as NTSC, PAL, 1080i/50, 1080i/60,
Custom), when the synchronization mode is "Select", the specified line and the
specified field can be selected to trigger.
The following table shows the corresponding relations between line and field
for all video standards (except for Custom)
Standard
Field 1
Field 2
NTSC
1 to 263
1 to 262