3-Point Calibration
1. Enter the Compass Mode.
l
Navigating Between Modes
2. Hold down (A) for at least two seconds.
This displays the Digital Compass Mode
setting screen.
Pointer
3. Use (A) and (D) to move the pointer to
[CALIBRATION].
4. Press (C).
5. Use (A) and (D) to move the pointer to [3-
POINT].
6. Press (C).
This displays the 3-point calibration
screen.
7. While keeping the watch horizontal, press
(C).
This starts calibration of the first point,
which causes [PLEASE WAIT] to appear
on the display. [ROTATE 180°] will appear
when calibration is successful.
8. Keeping the LCD of the watch pointing
upwards, rotate it 180 degrees. Be as
exact as possible.
9. While keeping the watch horizontal, press
(C).
This starts calibration of the second point,
which causes [PLEASE WAIT] to appear
on the display. [TURN OVER] will appear
when calibration is successful.
10. Turn the watch over so the LCD is pointing
at the ground.
Ground
11. While keeping the watch horizontal, press
(C).
This starts calibration of the third point,
which causes [PLEASE WAIT] to appear
on the display. [SUCCESSFUL] will
appear when calibration is successful. A
few seconds later, the watch will return to
the Digital Compass screen.
Note
If the calibration operation fails, the
message [FAILED RETRY?] will
appear. To retry calibration, press (C).
To stop a calibration operation, press
(E).
Pressing (E) during the above
procedure will return to the calibration
method selection screen.
Figure 8 calibration
1. Enter the Compass Mode.
l
Navigating Between Modes
2. Hold down (A) for at least two seconds.
This displays the Digital Compass Mode
setting screen.
Pointer
3. Use (A) and (D) to move the pointer to
[CALIBRATION].
4. Press (C).
5. Use (A) and (D) to move the pointer to
[FIGURE 8].
6. Press (C).
This displays the figure 8 calibration
screen.
When the screen shown above appears,
move your arm in a figure 8 pattern as
shown in the illustrations below.
Allow your wrist to twist.
Keep your arm as far as possible from
your body as you move it.
[SUCCESSFUL] will appear when
calibration is successful. A few seconds
later, the watch will return to the Digital
Compass screen.
Note
If the calibration operation fails, the
message [FAILED RETRY?] will
appear. To retry calibration, press (C).
To stop a calibration operation, press
(E).
Pressing (E) during the above
procedure will return to the calibration
method selection screen.