SPECIFICATIONS
Product Specifications 18K, 24k and 36k Outdoor Condensor
Multi‑Zone Flex 2 Indoor units 2 or 3 indoor units 2 to 4 indoor units
Model Name FPHMR18A3A FPHMR24A3A FPHMR36A3A
Gas R410A R410A R410A
Capacity Cooling Capacity 95 ºF Btu/h 18000 24000 32000
Heating Rated
Capacity
47 ºF Btu/h 18000 24000 36000
17 ºF Btu/h 12200 15400 22800
Heating
Maximum
Capacity
17 ºF Btu/h 20000 26000 40000
5 ºF Btu/h 18000 24000 36000
Cooling 95 ºF kW / / /
Btu/h 18000(7500~24000) 24000(8000~30200) 32000(12000~42000)
Heating 47 ºF kW / / /
Btu/h 18000(5800~28700) 24000(5200~37000) 36000(8000~52000)
Air flow CFM 3150 4000 5000
m3/h 1850 2353 2941
EER Btu/W•h 12.5 12.5 12.5
COP Btu/W•h 3.45 12.5 11.5
SEER Btu/W•h 22 22 21
HSPF Btu/W•h 11.0 11 11
Noise Level dB(A) (Max) 55 59 59
Operating
Range
Cooling °F 14~114.8 14~114.8 14~114.8
°C ‑10~46 ‑10~46 ‑10~46
Heating °F ‑13~75.2 ‑13~75.2 ‑13~75.2
°C ‑25~24 ‑25~24 ‑25~24
Compressor
model
Model EATF200D22UMT EATF250D22UMT EATF400D64UMTA
Brand GMCC GMCC GMCC
Electrical Data
Power V/Hz/ph 208~230/60/1 208~230/60/1 208~230/60/1
Power input Cooling 95 ºF W (Rated
Range)
1440(510~2610) 1920 (420~2640) 2520(700~5000)
Heating 47 ºF W Rated
Range)
1530(450~3510) 1920 (420~4020) 3060(600~6000)
Rated
current
Cooling 95 ºF A Rated
Range)
6.5 8.7 11
Heating 47 ºF A Rated
Range)
7.3 8.7 13
1. Test conditions
Cooling : Indoor: DB80 °C/ WB 67ºF Outdoor: DB95 °C/ WB75°F
Heating: Indoor: DB70 °C/ WB 60ºF Outdoor: DB47 °C/ WB 43 °F
2. The Sound Pressure Level is based on the following conditions:
Outdoor unit:
Measure the noise value of 3 points, the points are 3’(ft) in front of the three sides of the unit surface.
(front/left/right)and height =1/2(unit height +3) ft from floor level, and calculate the weighted average of the noise.
3. The above data was measured in an anechoic chamber. Please take into consideration reflected sound of your specific
application environment.
4. All specifications are subjected to change by the manufacturer without prior notice.