Weil-McLain EVERGREEN PRO EVG-220 Gas Boiler Evergreen High Efficiency Gas Boiler

User Manual - Page 130

For EVERGREEN PRO EVG-220.

PDF File Manual, 136 pages, Read Online | Download pdf file

EVERGREEN PRO EVG-220 photo
Loading ...
Loading ...
Loading ...
Part number 550-100-211/0122
– 130 –

Boiler
Model
Shipping
weight
Operating
weight
Water
content
Waterowrate
perboiler
Vent/airpipe
size:
(Provide a
separate vent for
each boiler)
Electrical
service
required
Pounds
per boiler
Pounds
per boiler
Gallons
per boiler
GPM
@ 20°F rise
GPM
@ 40°F rise
Amps
per boiler
Note 4 Note 5 Note 3
EVG 220 215 190 4.6 22 11 3” or 4” 15.0
EVG299/300 260 255 7.0 30 15 4” 15.0
EVG 399 260 255 6.7 40 20 4” 15.0
Notes
Based on standard test procedures outlined by DOE for individual boilers.
2
Net water ratings are based on piping and pickup allowance of 1.15. Consult Weil-McLain Technical Services for other allowances.
3
Total amp requirement includes up to three circulators, not exceeding 2.2 amps per circulator.
Operating weight is the total weight of the boiler, including water.
5
Evergreen
®
220 vent/air pipes can be either 3” or 4” pipe.
Evergreen
®
299/300/399 vent/air pipes must be 4”.
All of the boilers will automatically de-rate as vent/air pipe length increases, due to the pressure loss through the piping. See
Figure123,page129 for details.
All Evergreen
®
installations require a separate vent pipe and termination for each boiler. Ventpipingcannotbemanifolded. Install and
terminate vents as described in vent/air installation instructions in this manual.
Combustion air piping can be individually piped or manifolded. See Advanced Manual for manifolded air piping.
Boilersin
system
Total
CSAinput
CSAOutput/DOE
Heatingcapacity
Boiler
H.P.
Netwater
ratings
Manifoldedcombustion
airductsize
Input,
MBH
Output,
MBH
- MBH
Square
inches
EVG 220 EVG299/300 EVG 399
- Note 1 - Note 2
2 440 412 12.3 358 220
2 598 560 16.7 486 300
2 798 766 22.9 666 400
3 660 618 18.5 537 330
3 897 840 25.1 729 450
3 1197 1149 34.4 999 600
4 880 824 24.6 716 440
4 1196 1120 33.5 972 600
4 1596 1532 45.8 1332 800
5 1100 1030 30.8 895 550
5 1495 1400 41.9 1215 750
5 1995 1915 57.3 1665 1000
6 1320 1236 36.9 1074 660
6 1794 1680 50.2 1458 900
6 2394 2298 68.7 1998 1200
7 1540 1442 43.1 1253 770
7 2093 1960 58.6 1701 1050
7 2793 2681 80.2 2331 1400
8 1760 1648 49.2 1432 880
8 2392 2240 67.0 1944 1200
8 3192 3064 91.6 2664 1600
Figure124 Ratings and engineering data — multiple Evergreen
®