Cleaning and maintenance
66
The seal is not airtight:
The sealing level selected is unsuitable
for the type of bag used.
Repeat the cycle using a higher sealing
level.
Too many consecutive sealing cycles.
Wait at least 2 minutes between one
cycle and the next in order to allow the
sealing bar to cool down.
The bag is larger than the sealing bar.
Use an adequately sized bag.
The edge of the bag is not positioned
correctly.
Position the edge of the bag at the centre
and make sure that it has no creases. The
bag should protrude 2 cm from the
sealing bar.
The edge of the bag is dirty.
Before placing the product in the bag,
fold the top over so that the outside
remains clean.
The sealing bar is dirty.
Clean the sealing bar as described in the
section “Cleaning the sealing bar”.
The sealing bar or the rubber profile in
the lid are damaged.
Contact the technical assistance service.
The rubber counter pressure profile of the
sealing bar is not uniform.
Smooth the rubber coating on the
sealing bar.
The indicator light flashes:
Excessive moisture in the pump.
Run the dehumidification cycle.
Vacuum seal cold foods (3°C) which
have been cleaned, washed and dried
beforehand.
The indicator light turns on and the
appliance emits a beep during the cycle:
The vacuum has not been started or the
lid has not been closed.
To start the cycle, gently press the glass
lid to start the vacuum.
Dirt on the seal of the glass lid.
Clean the seal and the internal chamber
with a soft damp cloth and dry
thoroughly.
Seal of glass lid broken.
Contact the technical assistance service.
The pump will not start due to the
protective device.
There are 2 buttons in the lower right
section of the appliance for resetting the
protective device.
P re s s t he 2 bu t to n s.
If the fault persists, contact the technical
assistance service.