User Manual - Page 42

For PDP-V402. Also, The document are for others Pioneer models: PDP-V402E, PDA-4003, PDK-4001, PDK-4002, PDK-4003, PDK-4004, PDK-4005, PDK-4006, PDK-5008, PDM-4001, PDA-4002, PDP-S03-LR

Loading ...
Loading ...
Loading ...
42
Special installation (Wall embedding (vertically wall-embedding equipment))
3.4.6 Wall embedding (vertically wall-embedding equipment)
This display is designed to accommodate embedding in a wall. Since the allowable range of outside-air temperature
depends on the installation conditions. Please observe the following conditions:
1 Use a metal mounting fixture that does not block the side slits or the back ventilation holes, and attach at a
minimum of four points. To avoid breaking the PDP panel, limit any twisting or bending stress applied to the
display to 1 mm or less.
2
Do not use cable clamps for this installation method. Cable clamps can interfere with proper ventilation and
result in device failure.
3 Installation conditions and ambient operating temperatures:
(1) If the space behind the wall is open (If there is no obstruction within 300 mm from the backside):
C
A
A
Install the display with
the fan on top.
A
A
100
mm
100
mm
Exhaust
* The same conditions apply to the working temperature requirements for a speaker system (PDP-S03-LR).
* When mounting the down converter (PDA-4003), the same working temperature conditions apply.
Working temperature requirements
100 mm
100 mm
PC-9800 (56.4Hz)
PC-9800 (70.1Hz)
A size VIDEO Machintosh (66.7Hz)
VGA (60Hz)
VGA (72.8Hz, 75Hz)
60 mm or less 0~40°C 0~40°C 0~40°C
60 mm or more and/or 150 mm or less 0~40°C 0~40°C 0~35°C