6) Setting the optimal angle
This metal fixture is infinitely variable in a 25° range. This
work requires two workers.
1. Loosen the left and right screws c of the vertical
frame.
2. Lowering the arm, press against the display to get
the best angle.
3. When the desired angle is achieved, tighten the
screws c on both sides.
When the monitor is flat against the wall, use screws to
connect the variable side and fixed side of the hook fixture
shown above. (Use screws in a.) Tighten the left-and
right-side screws c.
a
c
X
How to mount standard optional items (PDK-4006)
Wire, flat bar
After setting the angle, use screws
a and a wire or flat bar to prevent
the frame from opening.
Measure the degree of opening relative
to the wall, X, to obtain the standard for
the set angle.
X Angle
117 mm 5°
173 mm 10°
229 mm 15°
282 mm 20°
When the tilted angle is 5 degrees or less, make sure to secure it using wires or flat bars.