For SC800. Also, The document are for others Nilfisk models: 56112000(SC750-26D), 56112004(SC750-28D), 56112006(SC750-28C), 56112012(SC750 ST-26D), 56112013(SC750 ST-28C), 56112016(SC800-28D), 56112018(SC800- 28C), 56112024(SC800-32C), 56112028(SC800-34D), 56112032(SC800 ST-34D), 56112780 (SC70- 28R)

PDF File Manual, 164 pages, Read Online | Download pdf file

SC800 photo
Loading ...
Loading ...
Loading ...
Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 92
• Drive the actuator motor all the way up and down using jumper wires powered by bat-
tery posive and negave. Connect them to the two actuator motor wires at the Main
Machine Controller connector. (Pink wire at connector J1 pin 4 and Gray wire at connec-
tor J1 pin 5.) Change polarity to change direcon. Immediately remove jumper wires at
the end of motor travel.
• Monitor the ohmmeter. It should show an open circuit (no connuity) only when the
actuator is in the retracted posion. In all other posions it should show a closed circuit
(connuity).
 Check the middle posion switch.
• Put the black ohmmeter lead on the Brown wire at the J2 connector pin 2.
• Put the red ohmmeter lead on the Yellow wire at the J2 connector pin 11.
• Drive the actuator motor all the way up and down using jumper wires powered by bat-
tery posive and negave. Connect them to the two actuator motor wires at the Main
Machine Controller connector. (Pink wire at connector J1 pin 4 and Gray wire at connec-
tor J1 pin 5.) Change polarity to change direcon. Immediately remove jumper wires at
the end of motor travel.
• Monitor the ohmmeter. It should show an open circuit (no connuity) only when the
actuator is in the middle posion. In all other posions it should show a closed circuit
(connuity).
 Check the extended posion switch.
• Put the black ohmmeter lead on the Brown wire at the J2 connector pin 2.
• Put the red ohmmeter lead on the Green wire at the J2 connector pin 12.
• Drive the actuator motor all the way up and down using jumper wires powered by bat-
tery posive and negave. Connect them to the two actuator motor wires at the Main
Machine Controller connector. (Pink wire at connector J1 pin 4 and Gray wire at connec-
tor J1 pin 5.) Change polarity to change direcon. Immediately remove jumper wires at
the end of motor travel.
• Monitor the ohmmeter. It should show an open circuit (no connuity) only when the
actuator is in the extended posion. In all other posions it should show a closed circuit
(connuity).
• Wiring
• Main Machine Controller
Loading ...