For SC800. Also, The document are for others Nilfisk models: 56112000(SC750-26D), 56112004(SC750-28D), 56112006(SC750-28C), 56112012(SC750 ST-26D), 56112013(SC750 ST-28C), 56112016(SC800-28D), 56112018(SC800- 28C), 56112024(SC800-32C), 56112028(SC800-34D), 56112032(SC800 ST-34D), 56112780 (SC70- 28R)

PDF File Manual, 164 pages, Read Online | Download pdf file

SC800 photo
Loading ...
Loading ...
Loading ...
Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 155
Does Not Propel Forward or Reverse with No Trip Type set
In the event the machine will not propel and there are no Trip Codes or Trip Types to narrow down the problem area,
systemacally check the Drive Motor Controller power supplies, inputs and outputs. Use the Service Test Mode to speed
your diagnosis. Check to see if the Drive Motor Controller is sending signals to the Main Machine Controller that indicate
it is trying to move the machine. If it is, that conrms that the input requests to the Drive Motor Controller are good
and that it is trying to respond to them. Next, check to see if there is voltage across the motor terminals. If the voltage is
above 6 volts and the motor is not turning, the motor is the problem (Check the carbon brushes). If there is no voltage to
the motor, the controller or wiring has failed.
Possible Causes
• Baery voltage too low
• Controller not receiving input requests for travel
• Drive motor
• Drive motor controller
• Wiring