For SC800. Also, The document are for others Nilfisk models: 56112000(SC750-26D), 56112004(SC750-28D), 56112006(SC750-28C), 56112012(SC750 ST-26D), 56112013(SC750 ST-28C), 56112016(SC800-28D), 56112018(SC800- 28C), 56112024(SC800-32C), 56112028(SC800-34D), 56112032(SC800 ST-34D), 56112780 (SC70- 28R)

PDF File Manual, 164 pages, Read Online | Download pdf file

SC800 photo
Loading ...
Loading ...
Loading ...
Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 150
Trip Type Type Description Trip Code Code Description and Possible Causes
1 Low Battery Voltage 2C00 Low Battery Voltage.
This occurs when the controller detects that the battery volt-
age has fallen below approximately 13.5V. Check the condi-
tion of the batteries, connectors and relevant wiring to the
i-Drive.
If the trip is still present after the batteries, connectors and
wiring have been checked, the controller may be defective.
Refer to Section 3
1 Low Battery Voltage 2C01 Very Low Battery Voltage.
This occurs when the controller detects a sudden drop in bat-
tery voltage. Check the condition of the batteries, connectors
and relevant wiring to the i-Drive.
If the trip is still present after the batteries, connectors and
wiring have been checked, the controller may be defective.
Refer to Section 3.
2 Motor Open Circuit 3B01 Motor Open Circuit.
This occurs when the controller detects that the motor has be-
come disconnected at start-up or in standby. Check the motor,
connectors and relevant wiring to the i-Drive.
If the trip is still present after the motor, connectors and wir-
ing have been checked, the controller may be defective. Refer
to Section 3.
3 Motor Wiring Trip 3D02 Motor Shorted To Battery Positive.
This occurs when the controller detects that the motor wiring
has been shorted to Battery Positive. Check the motor, con-
nectors and relevant wiring to the i-Drive.
If the trip is still present after the motor, connectors and wir-
ing have been checked, the controller may be defective. Refer
to Section 3.
3 Motor Wiring Trip 3D03 Motor Shorted To Battery Negative.
This occurs when the controller detects that the motor wiring
has been shorted to Battery Negative. Check the motor, con-
nectors and relevant wiring to the i-Drive.
If the trip is still present after the motor, connectors and wir-
ing have been checked, the controller may be defective. Refer
to Section 3.