Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 76
Hour Meter
The hour meter keeps track of the run me of the scrub motors.
On-board Battery Charger
An oponal on-board baery charger is available. It aaches to the boom of the machine. See the Electrical System
chapter for more informaon. Early models used an S.P.E. charger. Later models use a Delta-Q charger. Early models can
be retroed to use the Delta-Q charger.
Wiring for On-board Charger
When the S.P.E charger is installed, the machine wiring at the Key Switch must be modied for the “interlock” circuit to
funcon properly. See the Electrical System chapter for more informaon.
To modify the Key Switch Wiring: (See Instrucon Sheet Form No. 56090019)
1. Move wire 022 (YEL/BRN) from Key Switch pin 1 to Key Switch pin 2.
2. Remove wire 017 (BRN) from the Key Switch and plug it into wire 010 (BRN) at connector X66.
3. Install wire 009 (WHT/BRN) on the Key Switch pin 1.