Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 25
LCD
Display
Code
ST
Blink
Code
Code
Denion
Explanaon / Code Seng Condions / Flash Indicator
/ Disables / Check
62 4,1 Soluon Solenoid Circuit
Stuck On
The Main Machine controller is sensing current ow
through its internal switch for the soluon solenoid cir-
cuit when it has not requested that the switch be turned
on. (Senses >= 20 m Amps for 5 seconds).
63 4,2 Brush Contactor Coil
Circuit Stuck On
The Main Machine controller is sensing current ow
through its internal switch for the Brush Contactor Coil
circuit when it has not requested that the switch be
turned on. (Senses >= 20 m Amps for 5 seconds).
64 4,3 Vacuum Contactor Coil
Circuit Stuck On
The Main Machine controller is sensing current ow
through its internal switch for the Vacuum Contactor
Coil circuit when it has not requested that the switch be
turned on. (Senses >= 20 m Amps for 5 seconds).
65 (N/A) Brush Remove Contactor
Coil Circuit Stuck On
The Main Machine controller is sensing current ow
through its internal switch for the Brush Remove Contac-
tor Coil circuit when it has not requested that the switch
be turned on. (Senses >= 20 m Amps for 5 seconds).
70 4,4 Corrupt Communicaon
From On-Board Baery
Charger
The Baery Charger did not properly repeat the charging
prole message back to the Main Machine Controller.