For SC800. Also, The document are for others Nilfisk models: 56112000(SC750-26D), 56112004(SC750-28D), 56112006(SC750-28C), 56112012(SC750 ST-26D), 56112013(SC750 ST-28C), 56112016(SC800-28D), 56112018(SC800- 28C), 56112024(SC800-32C), 56112028(SC800-34D), 56112032(SC800 ST-34D), 56112780 (SC70- 28R)

PDF File Manual, 164 pages, Read Online | Download pdf file

SC800 photo
Loading ...
Loading ...
Loading ...
Service Manual: SC750, SC800, SC 750 ST, SC800 ST
Form Number 56043150 Page 81
Troubleshooting
Vacuum Motor Does Not Turn On (Scrub function works)
Possible Causes:
• Defecve Vacuum Motor
• Defecve Vacuum Motor Contactor (Relay) K1
• Defecve Wiring
• Defecve

Good water pick up performance depends on the proper amount of air owing through the squeegee pickup tool. Air
entering the vacuum system before the pickup tool will reduce its ability to pick up water. Anything that restricts the
movement of air through the system will also reduce its ability to pick up water.
Possible Causes:
• Restricted air ow
o Clogged or kinked squeegee vacuum hose
o Clogged vacuum motor inlet or outlet port
• Damaged squeegees
• Air leaks
o Recovery tank lid gasket is not sealing
o Cracked squeegee vacuum hose
o Cracked recovery tank
• Vacuum motor is weak
Begin with a good visual inspecon of the system. Check the condion of the squeegees and the recovery hose. Take the
recovery hose o and rinse it out. Check the recover tank cover gasket condion. Repair any problems found.
If no visual problems are found, test the system using a vacuum gauge PN 56205281 and open- hole adapter. (See the
Special Tools Secon below. The adapter can be made from a piece of PVC pipe.)
1. Remove the vacuum hose from the squeegee tool.