Figure 7-11 Temperature Measurement Parameters
The available parameters descripons are as follows:
Temp. Detecon
When enabling the funcon, the device will authencate the permissions and at the same me
take the temperature. When disabling the device, the device will authencate the permissions
only.
Normal Temp.
Edit the threshold according to actual situaon. If the detected temperature is higher or lower
than the congured parameters, an alarm will be triggered. By default, the minimum value is
1 °C and the maximum value is 45 °C.
Temperature Compensaon
If the measured temperature is higher/lower than the actual object's temperature, you can set
the compensaon temperature here. Available range: -99 to 99.
Note
You can select the unit as celsius degree or fahrenheit degree.
Door Not Open (Abnormal Temperature)
When enabling the funcon, the door will not open when the detected temperature is higher or
lower than the congured temperature threshold. By default, the funcon is enabled.
Temp. Measurement Only
When enabling the funcon, the device will not authencate the permissions, but only take the
temperature. When disabling the funcon, the device will authencate the permissions and at
the same me take the temperature.
DS-K1T690 Series Face Recognion Terminal User Manual