management system (CMS) soware installed. The alarm host IP refers to the IP address of
the remote PC on which the CMS soware (e.g., iVMS-4200) is installed, and the alarm host
port (7200 by default) must be the same as the alarm monitoring port congured in the
soware.
Server Port
Server port (8000 by default) should be congured for remote client soware access and its
valid range is 2000 to 65535.
HTTP Port
HTTP port (80 by default) should be congured for remote Web browser access.
Mulcast IP
Mulcast can be congured to enable Live View for cameras that exceed the maximum
number allowed through network. Both IPv4 and IPv6 are available for mulcast IP address.
For IPv4, it covers Class-D IP ranging from 224.0.0.0 to 239.255.255.255 and it is
recommended to use an IP address ranging from 239.252.0.0 to 239.255.255.255. When
adding a device to the CMS soware, the mulcast address must be the same as that of the
device.
RTSP Port
RTSP (Real Time Streaming Protocol) is a network control protocol designed to control
streaming media servers. The port is 554 by default.
Enhanced SDK Service Port
The enhanced SDK service adopts TLS protocol over the SDK service that provides safer data
transmission. The port is 8443 by default.
3. Click Apply.
12.7 Congure ONVIF
ONVIF protocol allows the connecon with third-party cameras. The added user accounts have the
permission to connect other devices via ONVIF protocol.
Steps
1. Go to Maintenance → System Service → ONVIF .
2. Check Enable ONVIF to enable the ONVIF access management.
Note
ONVIF protocol is disabled by default.
3. Click Add.
4. Enter User Name, and Password