6-18
Phase error (to reference conditions): < ± 0.5 degrees
Temperature coefficient: 0.005 % of range/ °C
Safety: 600 V CAT IV, type B sensor, pollution
degree 2
General Specification
Cable length: 2 m
Length of measuring head: 45 cm (18 inch)
Operating temperature range: 10 °C - +70 °C
Storage temperature range: 20 °C - +90 °C
Operating humidity: 10 % - 80 % (non-condensing)
Weight: Approx. 220 g
Order-number: 2540477
Reference Conditions
Environment temperature range: +18 °C to +26 °C
Humidity: 20 – 75 % rh
Current: Nominal value In, sinusoidal waveform, 48 –
65 Hz
Distortion factor: < 1 %. No DC component, stray field <
40 A/m, conductor centered within the Flexi
current sensor
Safety Standards
IEC/EN 61010-1 2
nd
edition
IEC/EN 61010-2-032
IEC/EN 61010-031
EMC Standards
EN61326 –1:2006
Accuracy (Typical, for 50/60 Hz)
Linearity, error in % of measured value, primary current in A: