Pin assignment:
Pin Signal Description
1 DCD Data Carrier Detect
2 RxD Receive Data
3 TxD Transmit Data
4 DTR Data Terminal Ready
5 GND Ground
6 DSR Data Set Ready
7 RTS Request To Send
8 CTS Clear To Send
9 RI Ring Indicator
G Feature connector
Specification of outputs / inputs:
Condition Voltage level
Low (inactive) 0 - 0.8 V
High (active) 2.5 - 5 V
Maximum load current: 5 mA.