Installation
*INSTALLATION*
80
Minimum plinth height
The minimum plinth height of the
KMDA 7473 FR-U, KMDA 7473 FL-U is:
- Guided recirculation mode: 100mm
- Plug&Play mode: 25mm
Cross-section of the ventilation
opening –
Plug&Play mode
The cross-section of the ventilation
opening must be at least 425cm².
If ventilation grilles are to be inserted
into the ventilation gaps, the ventila-
tion gaps must be larger than
425cm². The unobstructed airflow of
425cm² is calculated by adding up
the total area of ventilation openings
in the grilles.
The ventilation gaps must not be
covered or blocked in any way. They
must also be regularly dusted.
Housing unit back panel
The extraction ducting is laid behind the
housing unit back panel. The back
panel must be removable for mainten-
ance purposes.
Grease trap and cleaning flap
The hob must be installed such that the
grease trap and the cleaning flap are
easily accessible and can be removed
for cleaning.
Drilling template
The template supplied with the hob is
required for installation.
Plug&Play adapter
The Plug&Play adapter supplied with
the hob is required for operation in
Plug&Play mode.
Removing the transverse struts –
Plug&Play mode
The crossbeams in front of the top area
of the housing unit back panel must be
removed in order to install the
Plug&Play adapter.