Installation
*INSTALLATION*
75
Safety distance to niche cladding
If niche cladding is installed, a minimum safety distance must be maintained
between the worktop cut-out and the cladding, since high temperatures can alter
or damage these materials.
If the niche cladding is made from a combustible material (e.g. wood), a minimum
safety distance of 50mm must be maintained between the worktop cut-out and
the cladding.
If the niche cladding is made from a non-combustible material (e.g. metal, natural
stone, ceramic tiles), the minimum safety distance between the worktop cut-out
and the cladding will be 50mm minus the thickness of the cladding.
Example: 15mm thick niche cladding
50mm – 15mm = minimum safety distance of 35mm
Flush-fit installation Surface-mounted installation
aMasonry
bNiche cladding dimensionx= thickness of the niche cladding material
cWorktop
dWorktop cut-out
eMinimum safety distance to
combustible materials 50mm
non-combustible materials 50mm – dimension x